Setting tracking force

Prerequisite: The tonearm is balanced.

  1. Turn the counterweight ring until the centre line on the scale aligns with 0.
  2. Turn only the ring. The counterweight must not turn with it.
Align the scale ring with zero while holding the counterweight still
  1. Turn the counterweight and scale together to set the appropriate tracking force for the cartridge.
  2. For the supplied Ortofon 2M Red, the recommended tracking force is 1.8 g.
Turn the counterweight and scale together to set the recommended tracking force

Setting anti-skating force

Set the anti-skating scale to the same value as the tracking force. For the supplied cartridge, set it to 1.8.

Set the anti-skating dial to 1.8 for the supplied cartridge